Passivation Services per ASTM ASTM A967/A967M-13

Passivation Specifications Thank you for visiting the Advanced Plating Technologies Specification Database. Below is a technical summary of specification ASTM A967/A967M-13 from ASTM for Passivation. For more information on our full line of Passivation services please visit our passivation of stainless steel page. You can also request a quote or contact a member of our technical sales team for more information.

Revision: 2013
Finish: Passivation
Company: ASTM
Application: Chemical Passivation Treatments for Stainless Steel Parts via Nitric or Citric acid
Appearance: Varies
Plate Thickness: Nitric 1 – 20-25% nitric acid, 2.5% weight of sodium dichromate, Nitric 2 – 20-45% nitric acid, Nitric 3 – 20-25% nitric acid, Nitric 4 – 45-5 % nitric acid, Nitric 5 Other combinations of concentration of nitric acid with or without other chemical, including accelerants, inhibitors, or proprietary solutions, capable of producing parts that pass the specified test requirements; Citric 1 – 4-10% weight of citric acid, Citric 2 – 4-10% weight citric acid, Citric 3 – 4-10% weight citric acid, Citric 4 – Other combination of concentration of citric acid, with or without chemicals to enhance cleaning, including accelerants, inhibitors, or proprietary solutions capable of producing parts that pass the specified test requirements., Citric 5 – Other combinations of concentrations of citric acid, with or without other chemicals to enhance cleaning, including accelerants, inhibitors, or proprietary solutions capable of producing parts that pass the specified test requirements. Immersion bath to be controlled at a pH of 1.8-2.2
Strike Thickness: Nitric 1 – 20 mins at 120-130 degrees F, Nitric 2 – 30 mins at 70-90 degree, Nitric 3 – 20 mins at 120-140 degrees F, Nitric 4 – 30 mins at 120-130 degrees F, Nitric 5 – other combination of temperature and time capable of producing parts that pass the specified test requirements; Citric 1 – 4 mins at 140-160 degrees F, Citric 2 – 10 mins at 120-140 degrees F, Citric 3 – 20 mins at 70-120 degrees F, Citric 4 – Other combinations of temperature and time capable of producing parts that pass the specified test requirements, Citric 5 – Other combinations of temperature and time capable of producing parts that pass the specifies test requirements. Immersion bath to be controlled at pH of 1.8-2.2
Notes: per 6.2 and 7.2 - Immediately after removal from the passivating solution the parts shall be thoroughly rinsed, using stagnant, countercurrent, or spray washes singly or in combination, with or without a separate chemical treatment for neutralization of the passivation media (see Section 9), with a final rinse being carried out using water with a maximum total solids content of 200ppm.

Back to Spec Database

 


The information provided within the Advanced Plating Technologies’ database is for reference only and is not intended to be a comprehensive summary of any specification’s content.  Rather the database was designed to provide a brief summary of the specification’s subject matter to provide a sound context of the specification’s contents and engineering purpose. Advanced Plating Technologies cannot guarantee that the specifications contained therein are the most current revisions.  In addition, Advanced Plating has no affiliation with any of the organizations, agencies or companies contained within the database.  We hope you find the APT specification database a useful online resource and value any feedback you may have.

Although the data provided in this database has been obtained or adapted from sources that are believed by us to be reliable, no warranty expressed or implied is made by us regarding the accuracy, adequacy, completeness, reliability or usefulness of any data.  The data is provided strictly for reference purposes.  Only our standard product and service warranties apply to finished goods supplied by Advanced Plating Technologies.  To the extent that any third party company or agency is identified as a data source, Advanced Plating Technologies is not associated with such company or agency and that such company or agency is not identified for purposes of advertising, endorsement or recommendation by APT.  If you find any errors or omissions in the data, we encourage you to report them to us.